Cycle rating of 4,000 cycles is specified at >=70% retention (not 80%); solar capped at 400 W.

Nominal / Usable AC
1070 Wh (~910 Wh AC)
AC Continuous / Inductive Surge
1500 W / 3000 W
Solar Input & Idle Draw
400 W MPPT
16-60 V · Idle: N/D
Weight & Street Value
$0.60/useful Wh
23.8 lbs (10.8 kg) · $499–$599

1. Active Appliances & Duty Cycle

1 load active
Modern Refrigerator120V AC

Source: U.S. DOE / ENERGY STAR Flip Your Fridge & EnergyGuide

Quick Try:
Locked Model TelemetryCompatible

Jackery Explorer 1000 v2

1070 Wh · 1500 W
Estimated Runtime12.9 h
Total Avg Draw (+Idle)70.5 W52.5W load + 18.0W idle
Continuous AC150 W
Sustained Peak150 W
Inductive Surge1200 W
Inverter Continuous Load150 / 1500 W (10%)
Inductive Surge 1200 / 3000 W (40%)
Verified Pure Sine Wave output required for motors, medical devices, or Active PFC PSUs.
Disable AC Eco Mode / Auto-Shutoff so the inverter stays awake between compressor or float-switch cycles.
Show Auditable Physics Breakdown
Wh_effective = 1070 Wh × 0.850 (eff) × 1.00 (temp) × 1.00 (res) = 909.5 Wh
Total_draw = 52.50 W (avg load) + 18.0 W (AC idle) = 70.50 W
Runtime = 909.5 / 70.50 = 12.9 h
Daily Gross Battery Energy: 1991 Wh/day

Jackery Explorer 1000 v2 Verified Runtime Benchmark Table

Pre-computed at 68°F using 85% tested AC eff and tier default AC idle.

Compare in 1,000Wh-Class Portable Power Station Comparison (2025-2026) →
Appliance BenchmarkMode & Avg DrawSurge RequiredCompatibilityEst. Runtime
CPAP Machine (No Heat, DC 12V/24V)DC · 12.0 W total0 Wpass82.0 h
CPAP Machine (Humidifier + Heated Tube, AC)AC · 63.0 W total75 Wpass14.4 h
Full-Size Refrigerator (Modern ENERGY STAR)AC · 70.5 W total1200 Wpass12.9 h
Starlink Standard (Gen 3 Dish + Router)AC · 103.0 W total135 Wpass8.8 h
Wi-Fi Router + Cable/Fiber ModemAC · 33.0 W total0 Wpass27.6 h
Sump Pump 1/2 HP (Zoeller M98 LRA Spec)AC · 180.0 W total3400 WFail L35.1 h

Primary source: https://www.jackery.com/products/explorer-1000-v2 · Lab test: OutdoorGearLab (~85%, 910 Wh usable AC)

Frequently Asked Questions

How much usable AC energy does the Jackery Explorer 1000 v2 actually deliver?+
From 1070 Wh nominal LiFePO4 capacity, independent testing (OutdoorGearLab (~85%, 910 Wh usable AC)) measures roughly 85% AC efficiency (~910 Wh usable) before continuous AC inverter idle draw.
What is the surge and motor limit of the Jackery Explorer 1000 v2?+
The Jackery Explorer 1000 v2 delivers 1500 W continuous AC power and 3000 W peak inductive surge.
How is battery cycle life rated on the Jackery Explorer 1000 v2?+
Jackery Explorer 1000 v2 uses LiFePO4 cells rated for 4,000 cycles to >=70% capacity retention.